ISO 9001 certified bearing manufacturer · Full size and load data on every part

Enquiry list Get a quote

Try

Search the way engineers do

  • 6205 A designation, suffix or competitor interchange reference
  • 25×52×15 Bore × outside diameter × width in mm takes you straight to bearings that fit
  • 25×52 Bore and outside diameter only, when the width is open

Selection & sizing 6 min read

1 Inch Pillow Block Bearing: Which Unit Fits, and at What Shaft Height

A 1 inch pillow block bearing comes in several sizes that hold the shaft at different heights. Compare UCP205-16, UCPK205-16, UCSP205-16 and UCP305-16 before you order.

1 Inch Pillow Block Bearing

A 1 inch shaft measures 25.4 mm. The most common pillow block size near it, the metric UCP205, has a 25 mm bore. That 0.4 mm gap is why the first rule for a 1 inch pillow block bearing is to order the inch version, the UCP205-16, and not the plain UCP205.

The second rule catches more people. Several different units take a 1 inch shaft, and they hold it at different heights above the base. This guide lays out the common options with catalog numbers, so you can match the one you have or choose the right one for a new build.

Why “1 inch” isn’t enough to order a pillow block bearing#

The -16 suffix means the bore is in sixteenths of an inch, so 16/16 equals 1 inch. A unit with no suffix is metric. Our general pillow block bearings guide explains the rest of the part number, from the UC insert to the series digit.

What the suffix doesn’t tell you is how high the shaft sits. Here are four units that all fit a 1 inch shaft:

UnitDutyBase to shaft centerBolt spacingBolt sizeDynamic rating
UCPK205-16Standard1-27/64 in105 mm (4-1/8 in)M10Not listed
UCP205-16Standard1-7/16 in (36.5 mm)4-1/8 in (105 mm)3/8 in3,150 lbf (14.0 kN)
UCSP205-16Standard, heavier housing1-3/4 inSlotted, 5-1/8 to 5-5/8 in1/2 inNot listed
UCP305-16Heavy1-49/64 in (45 mm)5-3/16 in (132 mm)1/2 in4,766 lbf (21.2 kN)

The UCP205-16 figures come from PT International and AMI listings, with the rating from FYH’s catalog. The UCPK205-16 data comes from a Zoro listing for a Tritan unit, the UCSP205-16 from AMI, and the UCP305-16 from Timken and FYH.

What a mismatched shaft height does#

Look at the first two rows. Same 105 mm bolt spacing, same bolt holes, but the shaft center differs by 1/64 inch. Bolt one of each onto a frame and the shaft runs slightly uphill. That’s small, and the self-aligning insert will absorb some of it, but it’s a fault you built in on day one.

The bottom two rows, however, are worse. Swap a UCP205-16 for a UCP305-16 and the shaft rises by about 21/64 inch, and the bolt holes move apart by more than an inch. As a result, nothing lines up.

When a flange unit fits better than a 1 inch pillow block bearing#

Not every 1 inch support has to be a pillow block. Where the shaft passes through a wall or frame plate instead of running over a flat base, a flange unit such as our F2BC 100-TPSS stainless flange unit, with a stainless insert in a composite housing, carries a 1 inch shaft on a face mount. Our flange mount bearings guide compares the housing styles.

Standard 205 or heavy 305?#

Both carry a 1 inch shaft. However, the difference is the insert inside. Timken rates the UCP305-16 at 21,200 N dynamic and 10,900 N static, while FYH lists the UC205-16 at 14.0 kN dynamic and 7.85 kN static.

That gap grows fast when you turn it into hours. Ball bearing life follows L10 = (C/P)³, so take a steady 3 kN load at 500 RPM:

  • UC205-16: (14.0 / 3)³ = about 101.6 million revolutions, or about 3,400 hours.
  • UC305-16: (21.2 / 3)³ = about 352.9 million revolutions, or about 11,800 hours.

So the heavy unit lasts about 3.5 times as long under the same load. Our L10 bearing life guide explains what that number promises and what it doesn’t.

Still, the 305 has costs. It’s bigger, it needs 1/2 inch bolts instead of 3/8 inch, and the speed ceiling is a little lower: NTN lists 5,400 RPM for its UCP305 against 5,900 RPM for the UCP205. If your load is light and your frame is already drilled for a 205, there’s no reason to upsize.

Set screw or eccentric collar on a 1 inch shaft#

The UCP205-16 grips the shaft with set screws. An alternative is the eccentric collar unit, such as the UGP205-16, which a Motion listing shows with the same 3,150 lbf dynamic rating and a wider 1.75 inch inner race.

In general, set screws are the default and the easiest to fit. An eccentric collar locks by turning a collar against a stepped inner ring, then tightening one screw in the collar. Because the eccentric unit’s inner race is wider, check the length of free shaft beside the housing before you switch styles.

Whichever you pick, the fitting sequence matters more than the lock. Our guide to mounting a bearing without damaging it covers shaft cleaning and the order of tightening.

Measure the shaft before you blame the bearing#

Inch and metric shafts are easy to mix up by eye. Since 1959, the inch has been defined as exactly 25.4 mm, so a metric 25 mm shaft is 0.4 mm under 1 inch. That’s too much slack for a set screw unit to hold properly, and a UC205-16 insert will spin loose on it.

The reverse fails too. A 1 inch shaft won’t go into a metric UC205 bore without force, and forcing it damages the insert.

So measure with a micrometer or caliper in two or three places along the shaft where the bearing will sit. A worn shaft can measure smaller at the old bearing seat, and our article on shaft and housing fits explains why the fit on the shaft matters so much.

Seals and grease for a 1 inch pillow block bearing#

Most cast iron 1 inch pillow block bearing units come with contact seals and a grease fitting. The PT International UCP205-16 listed above, for example, is relubricatable with contact seals, and the heavy UCP305-16 uses a 1/8-27 NPT grease fitting tap.

For wet or dusty jobs, check the seal type before you order. Our comparison of sealed and shielded bearings explains the difference between contact seals and shields. Where the shaft ends inside the housing, a push-in end cover made for 205-size units, such as the 23 mm deep ECY 205 end cover or the 29 mm deep ECW 205 end cover for a longer shaft end, keeps grit off the seal and guards the shaft tip.

Quick answers on the 1 inch pillow block bearing#

What size is a UCP205-16?#

It fits a 1 inch shaft, with the shaft center 1-7/16 inch above the base and bolt holes 4-1/8 inch apart.

Can I use a UCP205 on a 1 inch shaft?#

No. The UCP205 has a 25 mm bore, which is 0.4 mm smaller than 1 inch. Order the UCP205-16.

Where can I get a 1 inch pillow block bearing in bulk?#

Send the unit number, shaft height and quantity through our contact page, and we’ll quote matching units or equivalents.

Before you order a replacement 1 inch pillow block bearing, write down three numbers from the old one: the shaft height from base to center, the bolt hole spacing and the bolt size. If any of those three differs from the table above, you have a different unit, and the number cast on the housing will tell you which.

China Bearing Manufacturer engineering team

Written by the engineers who answer enquiries, read failure reports and sign off inspection records. Every figure here is one we use when working through a real duty.

Ask a technical question

Questions are reviewed by an engineer before publication. Your email address is never published.

Working with us

From a bearing number to the right part, with one engineering contact.

Send a part number, a drawing or the markings from the old bearing. We confirm the equivalent, the options and the lead time.

  • Cross-reference helpOld markings or another brand's number, matched to an equivalent.
  • Selection supportLoad, speed and fit checked against your duty before you order.
  • Configurable optionsAsk about clearance, seals, cages and lubrication for your application.
  • Clear quotesPrice, quantity breaks and lead time set out in one reply.

Next step

Tell us about your machine, and we will find the bearing

Send the shaft size, speed, load, temperature and the part number you want to replace. That is all we need to send you matching options, prices and lead times.

Request a quotation +86 400 000 0000

Mon-Fri 08:30-18:00 (GMT+8)

Tell us what you need

Quantity and application are enough to start. We will come back with price, lead time and any better-suited designation.

Running speed, load, temperature, how it’s mounted and the part you’re replacing all help us get it right the first time.

We only use your details to reply to this enquiry. See our privacy policy.